presa-passante-zigbee-zr-plug-eu-m-1

ZR-PLUG-XX-M

ZigBee electricity meter and remote control Plug

  • Real Time Electricity Active Power Measurement up to 2,5 kW
  • Electricity Energy Counter
  • Remote switch up to 2,5 kW
  • Stand-by killer
  • Override push-button
  • Pass-Through Socket for many countries available: French (ZR-PLUG-FR-M), UK (ZR-PLUG-UK-M), Italian (ZR-PLUG-IT-M), US (ZR-PLUG-US-M)
  • ModBus profile on ZigBee platform
  • Router function

btm-scarica-scheda-en
btm-richiedi-info-en

ZigBee electricity meter and remote control Plug

The ZR-PLUG-EU-M passing plug is part of the ZB-Connection range. It includes an electric energy meter and a relay to turn on and turn off loads up to2,5 kW.

You can insert the ZR-PLUG-EU-M in a standard 230V socket and attach to it any kind of equipment. Once attached to a wireless ZigBee ZB-Connection network you can remotely switch on and switch off the device and always remotely measure the instant active power and the energy spent. Moreover is available stand-by killer and override button functions. You can set a power limit under which the device is meant to be in stand-by killer mode and so can be automatically turned off. With the override button the user can override the last command from the Gateway. Such tasks are carried out after simple Modbus commands sent to ZB-Connection network that transform them in wireless commands.
The device is continuously supplied by a 230 Vca output, so it can also work as a repeater or a “father” device for battery supplied sensors.

Technical Specs
General characteristics
Chip Ember EM250
Compatible IEEE 802.15.4
Stack EmberZnet 3.5.x (ZigBee PRO)
Modbus/RTU
Address settable through radio command
RF characteristics Frequency: 2405 MHz ÷ 2480 MHz
Modulation: DSSS
Nominal transmission power: 2mW (3 dBm)
Receiver sensitive: -95 dBm
Internal antenna gain: 0 dB
Outdoor/indoor range: 100m/30m
Supply 90/250 Vca; 1W; 50/60Hz
Measurement
Active Power [W]
Active Energy [Wh]
Energy consumption measurement time [second]
Relay
250V Contacts
Max load:
-Resistive: 10A
-Incandescent lamps: 10A
-Fluo lamps /transformers: 4A
Duration: 100.000 cycles with resistive load
Output 250V Contacts
Max load:
-Resistive: 10A
-Incandescent lamps: 10A
-Fluo lamps /transformers: 4A
Duration: 100.000 cycles with resistive load
Environment Parameters Operating temperature: 0 ÷ +50°C; <80% U.R. non condensing
Storage operation: -20 ÷ +70°C; <80% U.R. non condensing
Compliant with 2006/95/EEC, 89/336/EEC, 99/5/EEC directives
Product law applied
ETSI EN 300 328: Radio Compatibility for digital wide band transmissions
ETSI EN 301 489: Radio Compatibility
EN 55014-1:2006 + A 1:2009: Electromagnetic compatibility – Immunity
EN 61000-3-2:2006: Electromagnetic compatibility – Emissiond
EN 61000-3-3:2008: Electromagnetic compatibility – Emissions
EN 55014-2: Electromagnetic compatibility – Immunity